Start » Filter Reference » GigE Vision » GigEVision_GetStringParameter
Module: | GenICam |
---|
Gets parameter of type String from GigEVision device.
Name | Type | Description | |
---|---|---|---|
inAddress | GevAddress | GigE Vision Device identifying address (IP, MAC or Serial Number) | |
inParameterName | GevParameterName | Name of GenICam parameter node to access | |
inVerifyAccess | Bool | True to verify GenICam parameter access state before every read | |
outValue | String | Value retrieved from device parameter |
Description
This filter is intended for cooperation with GigE Vision® compliant devices. Its purpose is to get a value of device parameter using GenICam interface. Filter can be used to access device registers, stream chunked data or event message data.
Warning: Retrieving parameters from uncached device registers may be a time consuming operation that produce blocking network packets exchange at every filter execution.
This filter does not require other GigE Vision® filters in program (especially GigEVision_GrabImage is not obligatory), but can be used in any combination with them, including sharing access to single device with other filters. Device also does not have to be a transmitter.
Device address (inAddress port) is a textual definition of either IP, MAC or serial number. Use Device Manager (click "..." button in filter properties) to select appropriate address of connected device. For information on address type meaning and selecting device address see Device manager section in user manual.
This filter will interpret the value of inAddress port only during the first iteration of its parent Task, when the connection to the device is established. During the next iterations the filter will use previously established connection and subsequent changes in the device address will be ignored.
Parameter name (inParameterName port) must be an ID of GenICam parameter exported by the device. Each device model can have different parameter names and its meanings. Refer to the device documentation and use the GenICam settings browser (click "..." button in filter properties) to select appropriate name of the parameter (see: Device settings editor section).
The name of the parameter must point to a readable GenICam parameter providing "IString" interface or error will be raised upon filter execution.
For general information about working with GigE Vision devices, please refer to the following article.
Hints
- Interactively select a camera available in your network by defining the inAddress input.
- Choose inParameterName from those supported by your camera.
- The parameter value read from the camera will be available on the outValue output.
Complexity Level
This filter is available on Basic Complexity Level.
Disabled in Lite Edition
Filter Group
This filter is member of GigEVision_GetParameter filter group.
See Also
- GigEVision_GetRealParameter – Gets parameter of type Real from GigEVision device.
- GigEVision_GetEnumParameter – Gets parameter of type Enumeration from GigEVision device.
- GigEVision_GetBoolParameter – Gets parameter of type Bool from GigEVision device.
Application Notes - set of documents about connecting devices or establishing communication with Aurora Vision Studio.