Aurora Visio Studio TOP » Filter Reference » Hardware Support » Advantech SUSI » AdvantechSUSI_SetThermalProtection

AdvantechSUSI_SetThermalProtection


Module: ThirdParty

Sets thermal protection.

Name Type Range Description
Input value
inProtectionZone Integer 0 - 3
Input value
inSource AdvantechSUSIBoardTemperatureSensor
Input value
inEvent AdvantechSUSITemperatureEvent
Input value
inEventSend Real 1.0 - Unit is Kelvins. When thermal source goes over this value, SUSI will send event according event.
Input value
inEventClear Real 1.0 - Unit is Kelvins. When thermal source goes below this value, SUSI will clear event according event.

Remarks

I/O device driver software

This filter is intended to cooperate with a device using its vendor SDK. To be able to connect to a device, it is required to install Advantech SUSI SDK.

Add DLL path to system environment variable is required.

Recommended runtime version for Aurora Vision Studio usage is 4.

Setup low level system functionality e.g. watchdog may still affect the system after the program finished.

Complexity Level

This filter is available on Advanced Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.