Start » Filter Reference » Camera Support » Basler » Pylon_GenerateSoftwareTrigger

Pylon_GenerateSoftwareTrigger


Module: ThirdParty

Generates software trigger.

Name Type Range Description
Input value
inDeviceID String* Serial number, model name, user defined name or full name of camera device to be opened
Input value
inIgnoreWaiting Bool Waiting for previous trigger doesn't work with all cameras. E.g. for models A600 this value should be set to true.
Input value
inTimeout Integer* 100 -
Output value
outExecuted Bool Use only if inTimeout is set

Parallel execution

This filter cannot be placed in multiple Workers.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.