Hikrobot_GetInputParameters


Module: ThirdParty

Get input parameters.

Name Type Range Description
Input value
inDeviceID Integer* 1 - Device identification number - COM port number.
Input value
inPortNumber HikrobotPortNumber Device port number reference.
Output value
outEnableState Integer Enable state (1 is on, 0 is off).
Output value
outTriggerEdge HikrobotEdgeType Trigger edge.
Output value
outTriggerDelay Integer Trigger delay [ms].
Output value
outDebounceTime Integer Contact debounce time [ms].

Remarks

This filter allows to get the input parameters of a specific port of the device. The parameters are enable state, trigger edge, trigger delay and contact debounce time.

I/O device driver software

This filter is intended to cooperate with a device using its vendor SDK. To be able to connect to a device, it is required to install Hikrobot VC4000 SDK.

Add DLL path to system environment variable is required.

In some computer models, digital inputs and outputs may operate in reverse logic (true is low signal level). Please check your device.

Recommended Hikrobot VC4000 SDK version for Aurora Vision Studio usage is 1.2.0.

Device identification

inDeviceID field can be used to pick one of multiple I/Os connected to computer. DeviceID can be set to:

  • COM port number - the number of the COM port used to communicate with the I/O.

Complexity Level

This filter is available on Advanced Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.