Start » Filter Reference » Hardware Support » National Instruments » DAQmx_CreateCountEdgesChannel

DAQmx_CreateCountEdgesChannel


Module: ThirdParty

Creates a task and channel to count number of edges.

Name Type Description
Input value
inDeviceID String* Device alias, product name or serial number
Input value
inCounter String* Name of a counter used to create virtual channel
Input value
inActiveEdge DAQmxActiveEdge Active edge for counting
Input value
inInitialCount Integer Initial value
Input value
inCountDirection DAQmxCountDirection Type of counting (incrementing and decrementing values)
Output value
outTaskID DAQmxTaskID ID of a created task

Remarks

Device driver software

This filter is intended to cooperate with digital I/O cards using its vendor driver software. To be able to connect to a card it is required to install NI-DAQmx driver software. Currently Aurora Vision Studio requires NI-DAQmx version 23.3.

NI-DAQmx driver software can be downloaded from the following website: https://www.ni.com/pl-pl/support/downloads/drivers/download.ni-daq-mx.html#480879.

Device identification

When there is only one device connected to computer, inDeviceID field can be set to Auto. In this situation first available device will be found and connected.

inDeviceID can be used to pick one of multiple devices connected to computer. Set this field to Device alias (for example "Dev1"), product name or serial number. This parameters should be available in Measurement & Automation Explorer.

User manual

For more informations about using this filters please follow the link: Working with National Instruments devices.

Parallel execution

This filter cannot be placed in multiple Workers.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, Aurora Vision Studio Professional version.

See Also